An Analysis of Energy Consumption in the Campus Building’s Operation (Case Study: The Building of Faculty of Engineering and Department of Civil and Environmental Engineering, Universitas Gadjah Mada)

https://doi.org/10.22146/jcef.27642

Syarifudin Syarifudin(1*), Ashar Saputra(2), Suprapto Siswosukarto(3)

(1) Politeknik Negeri Nunukan, Nunukan
(2) Department of Civil and Environmental Engineering, Universitas Gadjah Mada, Yogyakarta
(3) Department of Civil and Environmental Engineering, Universitas Gadjah Mada, Yogyakarta
(*) Corresponding Author

Abstract


Energy Consumption Intensity (IKE) is an indicator that is used to determine the amount of energy used per area by an air-conditioned building within a month or a year as a reference to determine how much energy conservation can be done in the building. To determine the energy consumption of buildings and to determine the savings opportunities, there should be an effort to review the energy consumption through energy audits. In this research, energy consumption analysis was conducted at the Main Office building of the Faculty of Engineering (KPFT) and Department of Civil Engineering and Environmental (CEED) of UniversitasGadjah Mada Yogyakarta. The analysis was conducted on the main variables of energy efficiency, namely: measurement of temperature and relative humidity, calculation of Overall Thermal Transfer Value (OTTV) and Roof Thermal Transfer Value (RTTV), calculation of Energy Consumption Intensity (IKE) in air-conditioned and non-air-conditioned rooms as well as an analysis of opportunities to increase the efficiency of energy consumption in the buildings.The results showed that the temperature and the relative humidity of the KPFT building = 28.4℃ and 62%, while CEED Building = 28.4℃ dan 65%. Calculation of average OTTV of the KPFT building = 17.61 W/m2 and CEED building = 43.05 W/m2. Average IKE of the KPFT building in 2015 was 3.25 kWh/m2/month and in 2016 was 3.45 kWh/m2/month, while the average IKE of CEED building in 2015 was 1.5 kWh/m2/month and in 2016 was 0.79 kWh/m2/month. Based on the calculation of IKE in both buildings, they are still considered in the category of efficient. However, based on the measurement of temperature and relative humidity, it shows that in both buildings air conditioning is still necessary to achieve the level of thermal comfort, therefore an increase of efficiency in the load is needed to avoid wastage.


Keywords


Energy Audit, IKE, Conventional Building, Thermal Comfort

Full Text:

PDF


References

ASEAN-USAID, 1992. Building Energy Conservation Project, Final Report, June 1992, United States: ASEAN Lawrence Berkeley Laboratory.

Badan Standarisasi Nasional, 2011. SNI 6197:2011 tentang Prosedur Audit Energi pada Bangunan Gedung. Jakarta: Badan Standarisasi Nasional.

Badan Standarisasi Nasional, 2011. SNI 6389:2011 tentang Konservasi Energi Selubung Bangunan pada Bangunan Gedung. Jakarta: Badan Standarisasi Nasional.

Krishan, A., 2001. Climate Responsive Architecture: A Design Handbook for Energy Efficient Buildings. New York: McGraw-Hill Book Company.

Marzuki, A. & Rusman, 2012. Audit Energi pada Bangunan Gedung Direksi PT. Perkebunan Nusantara XIII (Persero0, Pontianak: Department of Electrical Engineering, Politeknik Negeri Pontianak.

Ministry of Energy and Mineral Resources, 2012. Ministry Law No.13 Year 2012 Tentang Penghematan Pemakaian Energi Listrik. Jakarta: Directorate General of Energy Saving.

Satwiko, P., 2009. Fisika Bangunan [Physics of Building]. Yogyakarta: Penerbit Andi.

Syarifudin, 2017. Analisis Konsumsi Energi pada Operasional Bangunan Gedung Kampus [Analysis of Energy Consumption towards Campus Building Operational], Yogyakarta: Master Thesis, Faculty of Engineering, Universitas Gadjah Mada.

Yuliatna, F., 2015. Analisis Perbandingan Konsumsi Energi pada Kegiatan Operasional dan Pemeliharaan Bangunan Gedung dengan Konsep Green Building dan Bangunan Gedung Konvensional, Yogyakarta: Faculty of Engineering, Universitas Gadjah Mada.



DOI: https://doi.org/10.22146/jcef.27642

Article Metrics

Abstract views : 2706 | views : 2858

Refbacks

  • There are currently no refbacks.




Copyright (c) 2022 The Author(s)


The content of this website is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
ISSN 5249-5925 (online) | ISSN 2581-1037 (print)
Jl. Grafika No.2 Kampus UGM, Yogyakarta 55281
Email : jcef.ft@ugm.ac.id
Web Analytics JCEF Stats