Main Office building of the Faculty of Engineering (KPFT) is one of the buildings located within the complex of the Faculty of Engineering, Universitas Gadjah Mada. There is a plan to build a new building adjacent to the KPFT building. The design can interact simultaneously in support of earthquake so that the pounding effect can occur. The pounding effect due to earthquake loads is to improve the quality of KPFT building. This study applies numerical study to determine the effect of adding new structures around the old structure. This research uses 3 structure models, i.e. KPFT building without a wall (SKTD), the new Smart and Green Learning Center (SGLC) structure (SB), and the composite building (SG). This research uses linear time history analysis. There are 3 earthquake records including Superstition Hills-02, Darfield New Zealand, and El Mayor-Cucapah. The results shows story drift from the KPFT building (SKTD model) is reduced after the adjacent building has occurred. The performance level for SKTD models is Life Safety (LS), whereas the performance level for KPFT building after combining with the new structure is Operational (OP). The KPFT building after combining with new structure has a better performance level due to its drift ratio.


Keywords


Pounding effect; performance level; time history

Full Text:

PDF


References

Akhsan, A. Y., 2014. Evaluasi Kinerja Gedung Kantor Pusat Fakultas Teknik (KPFT) Universitas Gadjah Mada Terhadap Pengaruh Gempa Dengan Analisis Pushover [Evaluation of KPFT Building Performance of Universitas Gadjah Mada towards Earthquake by Pushover Analysis], Yogyakarta: Universitas Gadjah Mada.

ASCE, 2000. FEMA 356 - Prestandard and Commentary for The Seismic Rehabilitation of Buildings, Washington, D. C.: Federal Emergency Management Agency.

BSN, 2012. SNI 1726-2012 Standar Perencanaan Ketahanan Gempa Untuk Struktur Bangunan Gedung, Jakarta: Badan Standarisasi Nasional (BSN).

BSN, 2013. SNI 03-2847-2002 Tata Cara Perhitungan Struktur Beton untuk Bangunan Gedung, Jakarta: Badan Standarisasi Nasional (BSN).

Jamal, A. U., 2009. Karakteristik Dinamik Gedung KPTU Fakultas Teknik UGM dengan Manggunakan Seismometer, Yogyakarta: Universitas Gadjah Mada.

Maison, B. F. & Kasai, K., 1990. Analysis for Type of Structural Pounding. Journal of Structural Engineering, Volume 116, pp. 957-977.

Rojas, F. R., 2012. Pounding of an 18-Story Building during Recorded Earthquakes. Journal of Structural Engineering, Volume 138, pp. 1530-1544.

Sandra, D., 2007. Analisis Ulang Struktur Gedung KPFT FT UGM Terhadap Beban Gempa, Yogyakarta: Universitas Gadjah Mada.



DOI: https://doi.org/10.22146/jcef.41163

Article Metrics

Abstract views : 1717 | views : 2387

Refbacks

  • There are currently no refbacks.




Copyright (c) 2022 The Author(s)


The content of this website is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
ISSN 5249-5925 (online) | ISSN 2581-1037 (print)
Jl. Grafika No.2 Kampus UGM, Yogyakarta 55281
Email : jcef.ft@ugm.ac.id
Web Analytics JCEF Stats