Life Cycle Impact Assessment Priok Power Generation Unit: Comparison Based on Operating Time Span
Adam Wicaksono(1*), Heru Pujo Prayitno(2), Himawan Khalid Prabowo(3)
(1) Priok Power Generation Unit, PLN Indonesia Power, Jakarta, Indonesia
(2) Priok Power Generation Unit, PLN Indonesia Power, Jakarta, Indonesia
(3) Priok Power Generation Unit, PLN Indonesia Power, Jakarta, Indonesia
(*) Corresponding Author
Abstract
Priok Power Generation Unit (PGU) is a combined cycle power plant (CCPP) which is one of the national vital objects with a generating capacity of 2,723 MW which functions as a load follower and Peaker in the electricity network system. This study aims to look at the environmental impact performance resulting from plant operating patterns January-December in 2020 and 2022, which was carried out using the life cycle assessment (LCA) method with SimaPro. The method life cycle impact assessment uses the ReCipe and CML IA baseline methods. The purpose of this comparison is to see improvements in the environmental performance of generating units to support sustainability. The results of this study show that there has been a change in the results of the environmental impact assessment in the Green House Gases (GHG) and Land Use Change (LUC) are the impact categories with the most significant reduction, namely more than 90%. Meanwhile, water footprints are the only impact that experiences an increase in environmental impacts during the 2020 operating period compared to the 2022 operating period.
Keywords
Full Text:
PDFReferences
Annisa, R., et al., “Life cycle Assessment of natural gas combined cycle steam power generation systems in Indonesia: Case Study on Gresik power plant,” in IOP Conference Series: Earth and Environmental Science, IOP Publishing Ltd, Jun. 2021. doi: 10.1088/1755- 1315/753/1/012039.
Guinée, J., “Life Cycle Sustainability Assessment: What Is It and What Are Its Challenges?,” Taking Stock of Industrial Ecology, no. Cml, pp. 1–362, 2015, doi: 10.1007/978-3-319-20571-7.
Hauschild, M.Z., Rosenbaum, R.K., and Olsen, S.I., “Life Cycle Assessment.”
Ibrahim, T.K., et al., “The optimum performance of the combined cycle power plant: A comprehensive review,” Renewable and Sustainable Energy Reviews, vol. 79. Elsevier Ltd, pp. 459–474, 2017. doi: 10.1016/j.rser.2017.05.060.
ISO, “14040: Environmental management–life cycle assessment— Principles and framework,” International organization for standardization, vol. 2006, 2006.
ISO, “Environmental management - Life cycle assessment - Requirements and guidelines,” EN ISO 14044, vol. 37(7), pp. 3567–3585, 2006, doi: 10.3934/dcds.2017153.
Karapekmez and Dincer, I., “Comparative e ffi ciency and environmental impact assessments of a solar- assisted combined cycle with various fuels,” Appl Therm Eng, vol. 164, no. September 2019, p. 114409, 2020, doi: 10.1016/j.applthermaleng.2019.114409.
Pieragostini, C., Mussati, M.C., & Aguirre, P., “On process optimization considering LCA methodology,” In Journal of Environmental Management, Vol. 96(1), 43–54, 2012. Academic Press. https://doi.org/10.1016/j.jenvman.2011.10.014
R. Brizmohun, T. Ramjeawon, and A. Azapagic, “Life cycle assessment of electricity generation in Mauritius,” J Clean Prod, vol. 106, pp. 565–575, 2015, doi: 10.1016/j.jclepro.2014.11.033
Sinaga, P.D.L., Moersidik, S.S., and Hamzah, U.S., “Life Cycle Assessment of a combined cycle power plant in Indonesia,” in IOP Conference Series: Earth and Environmental Science, IOP Publishing Ltd, Apr. 2021. doi: 10.1088/1755-1315/716/1/012122.
Wicaksono, Muhammad, R., Pujiono, Prayitno, H., Budiono, D., and Valmay, A., “PT PLN Indonesia Power Priok Power Generation Unit : Life Cycle Assessment Report 2023 (in Indonesian),” 2023.
Wicaksono, Muhammad, R., Pujiono, Prayitno, H., Budiono, D., and Valmay, A., “PT PLN Indonesia Power Priok Power Generation Unit : Impact Assessment Report (in Indonesian),” Jakarta, 2023.
Wicaksono, Sodri, A., and Chairani, E., “Using multi-criteria decision analysis for sustainability of combined cycle power generation indicators in Indonesia: An industrial perspective,” IOP Conf Ser Earth Environ Sci, vol. 575(1), 2020, doi: 10.1088/1755- 1315/575/1/012162.
Wicaksono, Sodri, A., and Chairani, E., “Sustainability indicators for electric power generation assessment in Indonesia using snowballing method environment, social, and economic dimension,” E3S Web of Conferences, vol. 211, p. 03003, 2020, doi: 10.1051/e3sconf/202021103003.Article Metrics
Refbacks
- There are currently no refbacks.

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.