Enhancing the impact strength of acrylic resin base plate by adding non-dental E-glass fiber

https://doi.org/10.22146/majkedgiind.42939

Mara Gustina(1), Widjijono Widjijono(2), Endang Wahyuningtyas(3*)

(1) Vocation school of Dental Technician, Faculty of Dentistry, Institut Ilmu Kesehatan Bhakti Wiyata Kediri Dentistry Master Program, Faculty of Dentistry, Universitas Gadjah Mada, Yogyakarta
(2) Department of Biomaterial, Faculty of Dentistry, Universitas Gadjah Mada, Yogyakarta
(3) Department of Prosthodontics, Faculty of Dentistry, Universitas Gadjah Mada, Yogyakarta
(*) Corresponding Author

Abstract


Non-dental glass fiber is one of the materials that can be used to increase the impact strength of a acrylic resin base plate, containing a similar composition to that of dental e-glass fiber. Orientation and positions of fiber affect the reinforcement effectiveness. This research aimed to examine the effect of the orientation of non-dental glass fiber in the compression position on the impact strength of an acrylic resin base plate. The research was conducted on 16 acrylic resin plates with fiber (65 mm x 10 mm x 2.5 mm) addition. The samples were divided into 4 groups (combination of different woven orientation unidirectional, bidirectional woven in the compression position, and control). The material used in this study was heat-cured acrylic resin QC-20 brand, non-dental glass fiber (without any brand). Impact strength was tested using an impact testing machine. The data obtained were analyzed using one-way ANOVA test and LSD (p<0.05). In this research the impact strength of the base plate with the addition of fiber increased 8.54 ± 2.21; 13.21 ± 2.34; 16.81 ± 2.80 kJ/m2 compared to that of the control group, i.e. 4.98 ± 1.05 kJ/m2. One-way ANOVA test showed a significant effect (p<0.05) of the fiber orientation variations on the compression position. This research concluded that the addition of nondental e-glass fiber (composed of SiO2
52.56-56.88%), diameter 17.12–20.03 µm) in the compression zone increases the
impact strength of acrylic resin base plate. Fibers with unidirectional orientation
provides the highest increase in the impact strength of acrylic resin base plate.

Keywords


fiber orientation; impact strength; non-dental glass fiber

Full Text:

PDF PDF


References

1. Agtini MD. Persentation of denture wearing in Indonesia. Media litbang kesehatan. 2010; 2(20): 508.

2. Anusavice KJ, Shen C, Rawls HR. Phillips’ Sciences of Dental Materials, 5
th ed. St. Louis: Saunders; 2013. 61, 474-5, 481-91.

3 McCabe JF, Walls AWG. Applied Dental Materials, 9th ed. Oxford Blackwell: Publishing; 2008. 113.

4. Bosanceanu DN, Beldiman A, Baciu RE. Complete dentures fractures causes and
incidence. Romanian Journal of Oral Rehabilitation. 2017; 9(1): 54-59.

5. Nirwana I. Kekuatan transversa resin akrilik hybrid setelah penambahan glass fiber dengan metode berbeda. Dental Journal. 2006; 1: 1619.
doi: 10.20473/j.djmkg.v38.i1.p16-19

6. Meng T, Latta MA. Physical properties of four acrylic denture base resin. J Contemp Dent Pract. 2005; 6(4): 93-100.

7. Alla RK, Sajjan S, Alluri VR, Ginjupalli K, Upadhya N. Influence of fiber reinforcement on the properties of denture base resins. JBNB. 2013; 4: 91-97. doi: 10.4236/jbnb.2013.41012

8. Zhang M, Matinlinna JP. E-glass fiber reinforced composites in dental application.
Silicon. 2012; 4: 73-78. doi: 10.1007/s12633011-9075-x

9. Malick PK. Fiber Reinforced Composite Materials, Manufactur- ing and Design, 3
th ed. Francis: Boca, Raton; 2007. 49-173. 10. Garoushi K, Vallittu P. Fiber reinforced composites in fixed partial dentures. Libyan J Med. 2006; 1(1): 73-82. doi: 10.4176/060802

11. Khalil AA, Siswomiharjo W, Sunarintyas S. Efect of non dental glass fiber orientation of transverse strength of dental fiber reinforced composite. Jurnal Teknosain. 2016; 5(2): 104110. doi: 10.22146/teknosains.9131

12. Dikbas I, Gurbuz O, Unalan F. Impact strength of denture polymethyl methacrylate reinforced with different forms of E-glass fibers. Acta Odontol Scand. 2013; 71(3-4): 727-732. doi: 10.3109/00016357.2012.715198

13. Vojdani M, Khaledi. Transverse strength of reinforced denture base resin with metal wire and E-glass fibers. Dental Journal. 2006; 3(4): 167-172.



DOI: https://doi.org/10.22146/majkedgiind.42939

Article Metrics

Abstract views : 2909 | views : 1760 | views : 923

Refbacks

  • There are currently no refbacks.




Copyright (c) 2020 Majalah Kedokteran Gigi Indonesia

Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.


 

 View My Stats


real
time web analytics