Pengambilan Lentulo Patah Pada Perawatan Saluran Akar Gigi Molar Satu Kiri Bawah Nekrosis Pulpa
Muhammad Syafri(1*), Tunjung Nugraheni(2)
(1) Program Studi Konservasi Gigi, Program Pendidikan Dokter Gigi Spesialis Fakultas Kedokteran Gigi, Univeristas Gadjah Mada, Yogyakarta, Indonesia
(2) Bagian Konservasi Gigi, Fakultas Kedokteran Gigi, Universitas Gadjah Mada, Yogyakarta, Indonesia
(*) Corresponding Author
Abstract
Selama prosedur preparasi saluran akar, kemungkinan patahnya instrumen selalu ada. Saat ini instrumen yang patah dapat dikeluarkan dengan menggunakan alat ultrasonik seperti jarum Miller yang dihubungkan dengan tip ultrasonik endo, selain itu diperlukan juga akses dan visibilitas yang baik sehingga memudahkan operator untuk mengeluarkan instrumen yang patah tersebut. Tujuan laporan kasus ini adalah untuk melaporkan keberhasilan pengambilan lentulo patah di dalam saluran akar menggunakan jarum miller yang dihubungkan dengan tip ultrasonik endo dikombinasikan dengan hedstroem no 25. Dalam makalah ini dilaporkan satu kasus perawatan saluran akar gigi molar satu kiri bawah pulpitis irreversibel pada pasien wanita 20 tahun, namun terjadi patah lentulo saat pengaplikasian bahan sterilisasi saluran akar. Pengambilan lentulo berhasil dilakukan pada kunjungan kedua dengan menggunakan jarum miller yang dihubungkan dengan tip ultrasonik endo serta hedstroem file no 25. Visibilitas didapatkan dengan melakukan coronal flaring menggunakan heroshaper dari mikro mega yang dihubungkan dengan alat rotary. Setelah 1 minggu, gigi diobturasi dengan teknik single cone pada saluran akar distal dan teknik kondensasi lateral pada saluran akar mesiobukal dan mesiolingual. Pada kunjungan berikutnya, gigi direstorasi dengan resin komposit disertai pasak dentatus screw. Setelah 2 bulan diamati secara radiografis dan klinis, tidak ada keluhan dari pasien.
Broken Lentulo Removal During Root Canal Treatment On The First Molar Mandible Sinistra With Pulp Necrosis. During root canal preparation procedure, there is always potential for instrument breakage. Nowadays, broken instruments can be removed using ultrasonic instruments such as a needle miller connected to endo ultrasonic tip, but it needs good access and visibility in order to make it easier for the operator to remove the broken instruments. The aim of this case report is to present the successful removal of a broken lentulo left in a root canal by using smooth broach connected to a ultrasonic endo tip combined with an hedstroem file no 25. This paper reports a case of molar root canal treatment of the lower left irreversible pulpitis in 20 year-old female patient, but the incident of broken lentulo occured while applying root canal medicament. The effort to remove lentulo was successful on the second visits using a needle miller connected to endo ultrasonic tip and headstrom file no 25. Visibility was obtained by using a coronal flaring of micro mega hero shaper associated with the rotary tool. In the following week, the teeth was obturated with single cone technique on the distal root canal applying the lateral condensation technique on mesiolingual and mesiobuccal root canal. In the next visit, the teeth were restored with composite resin with dowel dentatus screw. After 2 months of being observed radiographically and clinically, there is no more complaint from the patientKeywords
Full Text:
PDFReferences
Ruddle CJ. Broken instrument removal the endodontic challenge. Dentistry Today. 2002; 1-6.
Spilli P, Parashos P, Messer HH. The impact of instrument on outcome of endodontic treatment. J Endod. 2005; 31 (12) : 845-850.
Cohen S, Bauman MA.et al.Endodontology, Stuttgart :Thieme. 2000
Martin D. Removal of fractured instrument with a new extractor: clinical cases. International Dentistry: African Edition. 2010; 1 (3) : 50-58.
Yared G, Bou Dagher F, Kulkarni K.Influence of torque control motors and the operator’s proficiency on protaper failures. Oral Surg Med Oral Radiol Endod. 2003; 96(2) : 229-233.
Ruddle CJ. Non-surgical Retreatment. J Endod. 2004; 30: 827-845.
Alomairy KH. Evaluating two techniques on removal of fractured rotary nickel titanium endodontic instruments from root canals: an in vitro study. J Endod. 2009; 35 (4):559-562
DOI: https://doi.org/10.22146/majkedgiind.8384
Article Metrics
Abstract views : 6981 | views : 13215Refbacks
- There are currently no refbacks.
Copyright (c) 2015 Majalah Kedokteran Gigi Indonesia