Fiber-Reinforced composite resin bridges as a treatment alternative for posterior missing tooth
Arief Waskitho(1*), Anggun Kharisma Putri(2)
(1) Department of Prosthodontics, Faculty of Dentistry, Universitas Muhammadiyah Yogyakarta, Yogyakarta, Indonesia
(2) Clinical Program, Faculty of Dentistry, Universitas Muhammadiyah Yogyakarta, Yogyakarta, Indonesia
(*) Corresponding Author
Abstract
Dental restoration alternatives for posterior missing tooth range from dental bridges to implant dentures. Fiber-reinforced composite (FRC) resin bridge is one option for the replacement of a single tooth missing. FRC bridge is known as an alternative replacement method for single posterior missing tooth with minimally invasive preparation of abutment teeth. The simplicity of the production method in the FRC bridge provides the possibility of a single-visit bridge treatment. This report aims to present two successful treatments for missing posterior tooth by two different methods of immediate restoration using the FRC resin bridge. Treatments were performed directly using two different fiber materials, pre-impregnated quartz unidirectional fiber, and quartz fiber post. The use of unidirectional quartz fiber and quartz fiber post in the posterior tooth exhibited superior results due to its strength and geometry of fiber placement. In conclusion, the fiber-reinforced composite bridge is a possible option for managing the upper posterior missing tooth.
Keywords
Full Text:
10. Arief WaskithoReferences
1. Staehle HJ, Sekundo C, Hieronymus H, Büsch C, Frese C. Replacing single missing teeth in
the posterior region using direct composite restorations: Survival and clinical quality. J Dent. 2021; 113: 103754. doi: 10.1016/j.jdent.2021.103754
2. Escobedo Martínez MF, Rodríguez López S, Valdés Fontela J, Olay García S, Mauvezín Quevedo M. A New technique for direct fabrication of fiber-reinforced composite bridge: a long-term clinical observation. Dent J (Basel). 2020; 8(2): 48. doi: 10.3390/dj8020048
3. Heo G, Lee EH, Kim JW, Cho KM, Park SH. Fiber-reinforced composite resin bridges:
an alternative method to treat root-fractured teeth. Restor Dent Endod. 2020; 45(1): e8.
doi: 10.5395/rde.2020.45.e8
4. Goguta LM, Candea A, Lungeanu D, Frandes M, Jivanescu A. Direct fiber-reinforced interim
fixed partial dentures: six-year survival study. J Prosthodont. 2019; 28(2): e604–608.
doi: 10.1111/jopr.12751
5. Perea L, Matinlinna JP, Tolvanen M, Lassila LV, Vallittu PK. Fiber-reinforced composite
fixed dental prostheses with various pontics. J Adhes Dent. 2014; 16(2): 161–168.
doi: 10.3290/j.jad.a30755
6. Aditama P, Sugiatno E, Indrastuti M. The effect of fiber type and position on the transverse strength of an fiber reinforced composite (FRC) bridge. Majalah Kedokteran Gigi Indonesia. 2020; 6(3): 143 – 148. doi: 10.22146/majkedgiind.44616
7. Vallittu P, Özcan M. Clinical Guide to Principles of Fiber-Reinforced Composites in Dentistry
1st ed. United Kingdom: Elsevier Woodhead Publishing; 2017. 59-60.
8. Edelhoff D, Liebermann A, Beuer F, Stimmelmayr M, Güth JF. Minimally invasive treatment options in fixed prosthodontics. Quintessence Int. 2016; 47(3): 207–216.
doi: 10.3290/j.qi.a35115
9. Desai H, Stewart CA, Finer Y. Minimally invasive therapies for the management of dental caries-a literature review. Dent J (Basel). 2021; 9(12): 147. doi: 10.3390/dj9120147
10. Pankratz V, Zimmer S, Marković L. Anterior fiber‐reinforced ribbon composite resin bridge—A case report. Clin Case Rep. 2018; 6(10): 1941–1946. doi: 10.1002/ccr3.1745
11. Shah D, Singh R, Gala V, Verma S, Fernandes G. Minimally invasive fiber-reinforced
composite (FRC) bridge for the missing tooth: a case report. IOSR Journal of Dental and
Medical Sciences. 2018; 17(3): 71-74. doi: 10.9790/0853-1703017174
12. Sharma S, Attokaran G, Singh KS, Jerry JJ, Ahmed N, Mitra N. Comparative evaluation of
fracture resistance of glass fiber reinforced, carbon, and quartz post in endodontically treated teeth: An in-vitro study. J Int Soc Prev Community Dent. 2016; 6(4): 373–376.
doi: 10.4103/2231-0762.186801
13. Perea-Lowery L, Vallittu PK. Framework design and pontics of fiber-reinforced composite fixed dental prostheses - An overview. J Prosthodont Res. 2018; 62(3): 281–286.
doi: 10.1016/j.jpor.2018.03.005
14. Tacir IH, Dirihan RS, Polat ZS, Salman GÖ, Vallittu P, Lassila L, Ayna E. Comparison of load-bearing capacities of 3-unit fiberreinforced composite adhesive bridges with different framework designs. Med Sci Monit. 2018; 24:4440–4448. doi: 10.12659/MSM.909271
15. Joda T, Zarone F, Ferrari M. The complete digital workflow in fixed prosthodontics: a
systematic review. BMC Oral Health. 2017; 17(1): 124. doi: 10.1186/s12903-017-0415-0
16. Izgi AD, Eskimez S, Kale E, Değer Y. Directly fabricated inlay-retained glass and
polyethylene fiber-reinforced composite fixed dental prostheses in posterior single missing
teeth: a short-term clinical observation. J Adhes Dent. 2011; 13(4): 383–391.
doi: 10.3290/j.jad.a19470
DOI: https://doi.org/10.22146/majkedgiind.85065
Article Metrics
Abstract views : 853 | views : 566Refbacks
- There are currently no refbacks.
Copyright (c) 2024 Majalah Kedokteran Gigi Indonesia
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.