Application of Draft Tube in the Reduction of Backmixing Rate in Oscillatory Flow in a Baffled Column

  • Mohd Sobri Takriff Department of Chemical and Process Engineering
  • Zuhrina Masyitah

Abstract

Oscillatory flow in a baffled tube/column is an efficient way to enhance mixing in a straight smooth column. However, liquid oscillation moving back and forth across the baffle causes backmixing which is a disadvantage when plug flow is desired. This paper presents results from a study conducted to reduce the backmixing rate in oscillatory flow in a baffled column with the use of a draft tube. Results of this study showed that backmixing increases with oscillationvelocity and decreases with liquid flow rate. The use of a draft tube reduces backmixing. The backmixing reduction is proportional to the ratio of L/Do'. However, the draft tube can not be extended too long because it disrupts the flow behavior in the column and creates dead zones near the baffle region. The draft tube length ismaximized by extending it to both sides of the baffle, provided that the L/Do on each side of the baffle is at 0.67 or less.

References

Brunold, C.R., Hunn, J.C.B., Mackley, M.R. and
Thomson, J.W. "Experimental Observations on Flow Patterns and Energy Losses for Oscillatory Flowin Ducts Containing Sharp Edges". Chem.Eng. Sci., 44, 1989, 1227-1244.
Hewgill, M.R., Mackley, M.R., Pandit, A.B. & Pannu,
S.S., Enhancement of Gas-Liquid Mass Transfer Using Oscillatory Flow in Baffled Tubes. Chem.Eng. Sci., 48(4), 1993, 799- 803.
Howes, T and Mackley, M.R. Experimental Axial
Dispersion for Oscillatory Flow Through a
Baffled Tube. Chem. Eng. Sci. 45, 1349-1358 (1990).
Ingham, J., Slater, M.J. and Retamales, J. "Single
Phase Axial Mixing Studies in Pulsed Sieve
Plate Liquid-Liquid Extraction Columns".
Trans. I ChemE. 72(A), 1995, 492-496.
Mackley, M.R. Using Oscillatory Flow to Improve
Performance. The Chem. Eng. February,1987.
Mackley, M.R."Process Innovation Using Oscillatory
Flow Within Baffled Tubes". Trans. I ChemE. 69, 1991, 197-199.
Magelli. F, Fajner. D, and Pasquali,G. "Multistage
Mixer Column III". Chem. Eng. Sci. 37, 1986, 141-145.
Ni, X. and Gough, P. "On The Discussion of Dimensionless Groups Governing Oscillatory Flow in a Baffled Tube". Chem. Eng. Sci. 52, 1997, 3209-3212.
Roberts, E.P.L. "The Simulation of Chaotic Advection for Application to Process Engineering". Trans.I ChemE. 69, 1991,208-210.
Takriff, M.S, Penney, W.R. and Fasano, J.B. "Interstage Backmixing of an Aerated Multistage Mechanically-Agitated, Compartmented Column". The Canadian
Journal of Chern.Eng. 76, 1998, 365-369.
Xu, B.C., "Interstage Backmixing inCompartmented
Agitated Columns: Experimental
Determination and Correlation". Ph.D.
Dissertation, University of Arkansas, 1994.
Vidaurri, F.C. & Sherk, F.T. "Low Backmixing in
Multistage Agitated Contactors Used as Reactors. AIChE Journal. 31(5), 1985, 705-710.
Published
2002-12-31
How to Cite
Takriff, M. S., & Masyitah, Z. (2002). Application of Draft Tube in the Reduction of Backmixing Rate in Oscillatory Flow in a Baffled Column. ASEAN Journal of Chemical Engineering, 2(1), 15-20. Retrieved from https://journal.ugm.ac.id/v3/AJChE/article/view/7513
Section
Articles