Penentuan Daerah Perlindungan Batang Petir

  • Bayu Purnomo Universitas Gadjah Mada
  • T. Haryono Universitas Gadjah Mada
Keywords: penangkal petir, sudut perlindungan, metode sudut perlindungan

Abstract

External lightning protection system consisting of a finial, down-conductor and grounding are important aspects in the installation of lightning rods. The study was conducted by using a finial rod copper that aims to study the protection angle of a lightning rod. High finial of the earth would determine the angle of protection desired. Based on this research, the object of protection is the angle between 85,6° - 89,3°. This suggests that a lightning rod has limitations in protecting an area. The larger the area to be protected, the more number of lightning rod needed.

References

Anderson, J.G, “Transmission Line Reference”, Book 345 KV & Above Electric Power Research Institude, 2nd, Ed, Chapter 12. , 1982.

Cahyadi Wijaya, “Studi Evaluasi Sistem Perlindungan Petir Eksternal dan Internal khusus gedung T di Universitas Kristen Petra”, Surabaya, 2004.

Syakur, Abdul dan Yuningtyastuti, “Sistem Proteksi Penangkal Petir pada Gedung Widya Puraya”, Surabaya, , 2006.

Nedi Gunawan, “Evaluasi sitem proteksi penangkal petir Eksternal gedung bandara Fatmawati Soekarno Bengkulu dengan metode Konvensional dan Elektrogeometri”, 2011.

Published
2015-06-04
How to Cite
Bayu Purnomo, & T. Haryono. (2015). Penentuan Daerah Perlindungan Batang Petir. Jurnal Nasional Teknik Elektro Dan Teknologi Informasi, 4(1), 56-61. Retrieved from https://journal.ugm.ac.id/v3/JNTETI/article/view/3035
Section
Articles