Perancangan Sistem Sensor dan Aktuator Nirkabel untuk Sistem SCADA Berbasis PLC

  • A. Agung Femin Himawan Instruktur Kejuruan Listrik Balai Latihan Kerja Industri Makassar
  • Zulfajri Basri Hasanuddin Universitas Hasanuddin
  • Faizal Arya Samman Universitas Hasanuddin
Keywords: SCADA, PLC, sensor nirkabel, aktuator nirkabel, WSN, WPAN

Abstract

In current PLC-based SCADA systems, sensor and actuator are generally connected to a PLC by wire. The wire however has many limitations, especially in term of flexibility. In the PLC-based SCADA system by wire, the number of the installed PLC will increase for each location that will be monitored and controlled. This research aims to design and implement a low cost, low power and reliable wireless sensor and actuator system, which can be used in the PLC-based SCADA system to overcome the limitations of wire media. The wirelesssensor and actuator system can also be used as an alternative to reduce the amount of the used PLC within the SCADA system. In this research, we have designed a wireless sensor and actuator system based on WPAN technology (IEEE 802.15.4), which is low cost, low power, and reliable. The results reveal that the wireless sensor and actuator system is able to operate well when they are implemented on the PLC-based SCADA system used to monitor and control the water filtration process in the tub filtration.

References

D. Bailey and E. Wright, Practical SCADA for Industry, IDC technologies, 2003.

Anoniym, “Trends in SCADA for Automated Water Systems,” Synchrony, Virginia, Nov. 2001.

H. Fouda, “Improving SCADA Operations Using Wireless Instrumentation,” White paper, Schneider Electric, April. 2010.

G. Zhao, “Wireless Sensor Network for Industrial Process Monitoring and Control: A Survey,” ISSN 1943-3581, Vol.3, No.1, Macrothink Institute, USA, 2011.

B. Firman, “Implementasi Komunikasi Data Berbasis Zigbee Pada SCADA PLTMH,” Jurnal Teknologi, Volume 5, Nomor 2, Des. 2012.

A. Nechibvute and C. Mudzingwa, “Wireless Sensor Network for SCADA and Industrial Control Systems,” International Journal of Engineering and Technology, Vol.3, No.12, Dec. 2013.

K. A. Bisyri, “Rancang Bangun Komunikasi Data Wireless Mikrokontroler Menggunakan Modul Xbee Zigbee,” skripsi, Institut Pertanian Bogor, Bogor, 2012.

R. Faludi, Building Wireless Sensor Networks, O’Reilly Media, 2011.

Product ManualFor XBee™/XBee-PRO™ OEM RF Modules, Digi International, 2009.

Vijeo Citect Configuration Training Manual Version 7.0, Citect, 2007.

Unity Pro Program Languages and Structure Reference Manual, Schneider Electric, 2009.

Speed Studio, “G1/2 water flow sensor data sheet,” Shenzhen, China.

National Semiconductor, “IC LM331 data sheet,”, USA.

MaxBotix, “HRLV-MaxSonar-Ez data sheet”, USA.

How to Cite
A. Agung Femin Himawan, Zulfajri Basri Hasanuddin, & Faizal Arya Samman. (1). Perancangan Sistem Sensor dan Aktuator Nirkabel untuk Sistem SCADA Berbasis PLC. Jurnal Nasional Teknik Elektro Dan Teknologi Informasi, 3(3), 207-214. Retrieved from https://journal.ugm.ac.id/v3/JNTETI/article/view/3062
Section
Articles