APPLICATION OF NEUTRON ACTIVATION ANALYSIS IN CHARACTERIZATION OF ENVIRONMENTAL SRM SAMPLES
Diah Dwiana Lestiani(1*), Muhayatun Muhayatun(2), Natalia Adventini(3)
(1) Center of Nuclear Technology for Material and Radiometry, National Nuclear Energy Agency (BATAN), Jl. Tamansari 71 Bandung
(2) Center of Nuclear Technology for Material and Radiometry, National Nuclear Energy Agency (BATAN), Jl. Tamansari 71 Bandung
(3) Center of Nuclear Technology for Material and Radiometry, National Nuclear Energy Agency (BATAN), Jl. Tamansari 71 Bandung
(*) Corresponding Author
Abstract
Neutron activation analysis (NAA) is a nuclear technique that is excellent, multi-elemental, sensitive and has limit detection up to nanogram level. The application of NAA in analysis of Standard Reference Material (SRM) National Institute of Standard Technology (NIST) 1633b Coal Fly Ash and SRM NIST 1646a Estuarine Sediment was carried out for NAA laboratory inter-comparison program. The samples were distributed by Technology Centre for Nuclear Industry Material, National Nuclear Energy Agency as a coordinator of the inter-comparison program. The samples were irradiated in rabbit facility of G.A. Siwabessy reactor with neutron flux ~ 1013 n.cm-2.s-1, and counted with HPGe spectrometry gamma detector. Several trace elements in these samples were detected. The concentration of Al, Mg, K, Na and Ti in SRM NIST 1633b were 15.11, 7.35, 2.09, 0.192 and 0.756% respectively and the concentration of As, Cr, Mn, Se, V, Sb, Co, Cs, La, Sc and Sm were 137.0, 195.6, 129.4, 9.61, 305.8, 5.45, 56.2, 11.18, 83.73, 41.1 and 19.13 mg/kg respectively. The analysis result in SRM NIST 1646a of the concentration of Al and Na were 2.15 and 0.70% and the concentration of As, Cr, Co, La and Sc were 5.75, 36.3, 4.58, 15.67 and 4.00 mg/kg respectively. These results analysis had relative bias and u-test ranged from 0.4-11.3% and 0.15-2.25. The accuracy and precision evaluation based on International Atomic Energy Agency (IAEA) criteria was also applied. The result showed that NAA technique is applicable for the environmental samples analysis, and it also showed that the NAA laboratory in BATAN Bandung has a good performance.
Keywords
Full Text:
Full Text PDFReferences
[1] Chung, Y.S., Jeong, E.S., and Cho, S.Y., 1997, J. Radioanal. and Nucl. Chem., 217,1, 71-76.
[2] Glascock, M.D, 2004, University of Missouri Research Reactor (MURR), Columbia, MO. Website: http://archaeometry.missouri.edu/naa_overview.html
[3] Cohen, D.D., Bailey, G.M., and Kondepudi, R., 1996, Nucl. Instrum. Methods Phys. Res., Sect. B., 109/110, 218-226.
[4] Anonim, ISO/IEC 17025:2005, Persyaratan Umum Kompetensi Laboratorium Pengujian dan Laboratorium Kalibrasi, 2005.
[5] Zeiller, E., Campbell, M.J., and Robert D.,1997, J. Anal. At. Spectrom., 12, 1011–1015.
[6] Yusuf, S., Rukihati, dan Kuntoro, I., 2008, Prosiding Seminar Nasional AAN 2008, Forum AAN Indonesia, Bandung.
[7] Ehmann, W.D., Diane E., and Vance, 1991, Radiochemistry and Nuclear Methods of Analysis. John Wiley & Sons, Inc. Volume 116. New York.
[8] Susetyo, W., 1984, Diktat Instrumentasi Kimia II Spektrometri Gamma, Pusdiklat BATAN, Jakarta.
[9] Anonymous, IAEA, 2003, Analytical Quality Control Services, Summary Report of the Proficiency Test for the IAEA Project RAS/2/020: Quality Assurance an Quality Control of Nuclear Analytical Techniques, Seibersdorf, Austria.
[10] Anonymous, National Institute of Standards Technology, December 2004. Certificate of SRM NIST 1633b Coal Fly Ash.
[11] Anonymous, National Institute of Standards Technology, 2004. Certificate of SRM NIST 1646a Estuarine Sediment.
DOI: https://doi.org/10.22146/ijc.21535
Article Metrics
Abstract views : 2264 | views : 3687Copyright (c) 2010 Indonesian Journal of Chemistry
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Indonesian Journal of Chemistry (ISSN 1411-9420 /e-ISSN 2460-1578) - Chemistry Department, Universitas Gadjah Mada, Indonesia.
View The Statistics of Indones. J. Chem.