Comparison of corneal endothelial cell count and intraocular pressure in pure-dispersive and dispersive-cohesive viscoelastic protection in phacoemulsification surgery

https://doi.org/10.19106/JMedScie/0050032018013

Agung Nugroho(1*), R Haryo Yudono(2)

(1) Department of Ophthalmology, Faculty of Medicine, Public Health and Nursing, Universitas Gadjah Mada/Dr. Sardjito General Hospital, Yogyakarta, Indonesia
(2) Department of Ophthalmology, Faculty of Medicine, Public Health and Nursing, Universitas Gadjah Mada/Dr. Sardjito General Hospital, Yogyakarta, Indonesia
(*) Corresponding Author

Abstract


There are so many aspects should be regarded when use viscoelastic device during phacoemulsification surgery. The advantages and disadvantages of pure-dispersive viscoelastic and dispersive-cohesive viscoelastic always require more our attention to use it conveniently. The purpose of the study was to compare between pure-dispersive viscoelastic versus dispersive-cohesive viscoelastic in phacoemulsification surgery in that of corneal endothelial cell count and intraocular pressure (IOP) change. This was a cross-sectional study involving 41 eligible patients who underwent phacoemulsification surgery by single operator. Data including characteristics of cataract patients, corneal endothelial cell count and IOP were taken before and after surgery. Data of characteristics of cataract patients were reported descriptively and compared using Anova and t-test. The mean change in corneal endothelial cell count on pure-dispersive viscoelastic group (71.99±71.20 cells/mm²) was lower than that on the dispersive-cohesive viscoelastic group (117.62±78.29 cells/mm²). However, it was not significantly different. The mean change in IOP on pure-dispersive viscoelastic group (0.75±1.626 mmHg) was significantly lower than that on dispersive-cohesive viscoelastic group (1.90±0.995 mmHg) (p=0.000). In conclusion, the increase of IOP in dispersive-cohesive viscoelastic group is higher than that on pure-dispersive viscoelastic group. However, there is no significant difference of the mean change in corneal endothelial cell on the both groups.

Keywords


phacoemulsification - corneal endothelial cell - intraocular pressure – viscoelastic – pure-dispersive - dispersive-cohesive

Full Text:

PDF



DOI: https://doi.org/10.19106/JMedScie/0050032018013

Article Metrics

Abstract views : 886 | views : 1740




Copyright (c) 2019 Agung Nugroho, R Haryo Yudono

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

View My Stats

 

Creative Commons License
Journal of the Medical Sciences (Berkala Ilmu Kedokteran) by  Universitas Gadjah Mada is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Based on a work at http://jurnal.ugm.ac.id/bik/.